Electronic level crossing device GFSU LC09
Electronic level crossing devices GFSU LC09 consists of intelligent programmable logic control system, whose solution can be easily adjusted to standard conditions of level crossing and also to specific customer requests. Proper functioning of the device is constantly controlled in one permanently occupied official premises or in telecomand center. Level crossing signals and half-barriers are activated by coming of the rail vehicle and in case of any interference.
Automatic turning off of level crossing is performed by crossing over and leaving of a railway vehicle over double disconnection devices. In case of malfunction on the level crossing devices, the main signals that protect level crossing are automatically set to give the signal for prohibited driving. Basic power supply of the device is performed from distributive network. In case of basic power supply failure, eight-hour reserve is provided from accumulator batteries.
ADVANTAGES OF ELECTRONIC LEVEL CROSSING GFSU LC09
- Simple modification in case of any change and expansion.
- Low cost of maintenance and repair with preventive diagnostics.
- Adjustable parameters of the barrier (speed of lowering / lifting of semi-fender or fender).
- Application software independent from hardware.
- Application software, also the number of external parts is adjustable.
SOFTWARE
GFSU LC09 provides storing of all events and commands in it’s internal memory and remote control and reading of journal events using relevant interface equipment. For better and higher quality maintenance of level crossing we use control and diagnostics software package at regular and emergency checks. Control and diagnostics package can be upgraded, which makes it flexible in terms of wide range of requirements.